Full HD infrared camera ImageIR ® 10300 Series

With the ImageIR ® 10300, users from industry and science for the first time can use a radiometric infrared camera whose cooled photon detector permits images in the format (1,920 × 1,536) IR pixels.

  • Full HD resolution of about 3 Megapixels
  • Pixel pitch of 10 µm
  • Thermal resolution better than 0.03 K
  • Measurement accuracy ± 1 °C or ± 1 %
  • High-speed recording with previously unknown image quality

Details about infrared camera


Spectral range

(3.6 … 4.9) μm

linie

Pitch

10 µm

linie

Detector

InSb

linie

Detector format (IR pixels)

(1,920 × 1,536)

linie

Image acquisition

Snapshot

linie

Readout mode

ITR/IWR

linie

Aperture ratio

f/2.0 or f/3.0

linie

Detector cooling

Stirling cooler

linie

MTTF

15,000 h

linie

Temperature measuring range

(-40 ... 500) °C

linie

Measurement accuracy

± 1 °C or ± 1 %

linie

Temperature resolution @ 30 °C

Up to 0.03 K

linie

Frame rate
(full frame mode/(960 x 768))

100 Hz/300 Hz, (identical FOV)

linie

Window mode

Yes

linie

Focus

Manually, motorised or automatically*

linie

Dynamic range

13 bit

linie

Integration time

(1 … 20,000) µs increments up to 1 µs

linie

Rotating aperture wheel and filter wheel*

Up to 5 positions

linie

Multi Integration Time

Yes

linie

Interfaces

10 GigE, HDMI*

linie

Trigger

3 IN/2 OUT, TTL

linie

Tripod adapter

1/4" and 3/8" photo thread, 2 x M5

linie

Power supply

24 V DC, wide-range power supply (100 ... 240) V AC

linie

Storage temperature

(-40 ... 70) °C

linie

Operation temperature

(-20 ... 50) °C

linie

Protection degree

IP54, IEC 60529

linie

Impact strength/vibration resistance in operation

2 G, IEC 68-2-29/26

linie

Dimensions

(241 × 123 × 160) mm

linie

Weight

4.7 kg (without lens)

linie

 

*Depending on model

The top model of the ImageIR ® series symbolises InfraTec's accumulated knowledge from 25 years of applied thermography. It incorporates the consequence of our own development efforts, which strive consistently for perfection. And it reflects the skills of experienced engineers, who check each component's suitability to produce in the end a precise high-tech measurement instrument.

The ImageIR ® 10300 with its enormous geometric resolution marks the current highpoint of the high-end camera series produced in Dresden. The detector format, in combination with the small pitch dimension of 10 µm, ensures that measurement, inspection and surveillance tasks can be solved even more efficiently than before. Everywhere that very fine structures need to be analysed on large-surface measurement objects, for example, users save time, effort and thus costs.

Measurement results in previously unknown image quality

For the acquisition and representation of temperature distribution on the surface of the measuring and test objects the detector format plays a crucial role. The detector of the ImageIR ® 10300 in the format of (1,920 × 1,536) IR pixels allows Full HD quality images. The almost 3,000,000 IR pixels therefore provide about ten times more individual temperature measurement points than the thermal imaging cameras with a detector format of (640 x 480) IR pixels. From this enormous increase of information users benefit from thermal images, which attain almost photo quality.

Recognise the smallest temperature differences, thanks to a high thermal sensitivity

Beside the highly sensitive detector especially the first class and high-luminosity optics are responsible for the camera's outstanding thermal sensitivity. Their large aperture increases the share of radiation that can be received and so results in extremely brilliant noise-free thermal images. As a result, the camera suits for a versatile field of applications. This includes measurement and inspection tasks in the area of research and development for industry and science as well as surveillance tasks within the context of security measures.

Create and transmit thermograms at high speed

Such sophisticated applications make special demands on the capability of infrared cameras. For that reason, InfraTec itself developed a corresponding network adapter for the ImageIR ® 10300's 10 Gigabit Ethernet interface that handles this extremely fast transmission standard. The network adapter works with plug-in, modular, optical or electrical transceiver modules that are easy to replace and are designated SFP+. Despite the extremely large detector format, complete picture transmission achieves an image rate of up to 100 Hz. Through this, users can store large amounts of measurement data on a computer in the shortest amount of time. Different 10 GigE glass-fibre SFP+ support transmission ranges of up to ten kilometres while simultaneously maintaining complete insensitivity to electromagnetic disturbances, even in the roughest industrial environment. Additional possibilities open up by using a Thunderbolt adapter. In this way the camera can be controlled via laptop, too. 

Always stay flexible with the modular system

Like the entire high-end camera series, the ImageIR ® 10300 is also made up of several modules. This simplifies individual adaptation to your demands. Numerous components can be retrofitted even after the original configuration is established. The modular design likewise includes the camera housing. Produced from high-strength aluminium, it is suited for use under rough environmental conditions due to its compact dimensions and low weight. The interfaces are equipped with industrial plug connectors that maintain the protection degree.

Master the most complex measurement and inspection tasks yourself

High object temperatures or specific material characteristics of the measurement objects can make analysis with thermographic systems considerably more challenging. For such cases, InfraTec offers equipment with an optional aperture or filter wheel. Each is motorised and can be operated through the camera controller.

 

For example, if extremely high temperatures on objects are measured, the apertures weaken the respective radiation accordingly. With calibrated measurement ranges, a previously determined aperture is automatically selected and used for image recording.

 

If specific emission or transmission characteristics of the measurement object make the task more difficult, users can equip the ImageIR ® 10300 with a filter wheel. As a result, the camera's range of use is expanded to cover the area of spectral thermography. In this way, transmission is prevented with thin foils and only their purely emitted radiation is recorded for temperature measurement. The wheel offers room for up to five spectral filters and, accordingly, numerous variants, so the thermography system can be adapted to target the measurement and inspection task on site.

Use the trigger interface and software to work efficiently and conveniently

An integrated trigger interface ensures the highly precise, exactly repeatable triggering of fast processes. Two configurable inputs and outputs each serve to record external analog and digital signals synchronized with the image or to generate digital control signals for external devices. The powerful IRBIS ® 3 software family, developed by InfraTec, supports the ImageIR ® 10300 with a wide range of analysis and processing tools in complex thermographic investigations.

The following infrared camera models might also be of interest to you:

ImageIR ® 8300/9300 Z Serie
ImageIR ® 9300 Serie
ImageIR ® 8800 Serie
ImageIR ® 8300 Serie
ImageIR ® 8300 hp Serie
ImageIR ® 7300 Serie
ImageIR ® 5300 Serie
ImageIR ® 4300 Serie

Application areas for infrared camera

  • Spectral thermography
    Spectral thermography

    Using precision filters for specific applications you will measure exactly those spectral ranges being of interest to you.

  • High-Speed Thermography
    High-speed thermography

    Get even faster and analyze temperatures at highest process speeds.

  • Material testing
    Material testing

    Save time and costs by nondestructively testing components with infrared camera systems by InfraTec.

  • Thermal optimization
    Thermal optimization

    Identify possible problems already in the development phase well before serial production.

  • Electronics and electrical engineering
    Electronics and electrical engineering

    Measure temperature distributions of smallest electronic components with infrared camera systems.

  • Thermography in automotive industry
    Automotive industry

    Infrared camera systems help you to secure a high product quality in production and at your suppliers.

  • Thermography in aerospace industry
    Aerospace industry

    Comply with highest security demands by applying state-of-the-art infrared camera systems.

  • Thermography in glass industry
    Glass industry

    Measure correctly temperature distributions behind and on glass by using selected spectral filters.

  • Thermography in plastics industry
    Plastics industry

    Cost-efficiently control die-casting and extrusion processes by means of infrared camera systems.

  • Thermography in chemical industry
    Chemical industry

    Systematically control reactive process heat and display with infrared camera systems of InfraTec.

  • Thermography in the metallurgy
    Metallurgy

    Efficiently reduce the energy consumption of your metallurgic processes using infrared camera systems.

  • Investigation
    Investigation

    State-of-the-art infrared technology expands the options of the Police´s investigation capabilities via increasing range performance, 24/7 operation options and completely passive technology.

  • Surveillance at a SAR operation
    Surveillance

    Powerful, uncooled thermal sensors and innovative optical design create a maximum range performance and high image resolution for quick missions and long-term observation tasks.

  • Border guard
    Border guard

    Comprehensive guarding of border areas and the related hinterland is perfectly handled by mobile infrared cameras with top-class range performance. Their mobility and efficiency supports contemporary border guard units even during very limited observation conditions.

  • Harbour protection
    Harbour protection

    All over the world seaports and inner harbors are very special critical infrastructure locations. By using mobile infrared cameras extended and inaccessible units can be guarded safely and comprehensively.

  • Security - Site protection
    Site protection

    High-resolution, long-range infrared cameras allow efficient guarding and protection of critical infrastructure areas all around the clock. Dedicated using of infrared systems allow in-time realization of effective counteractive measures.

  • Security - Search and rescue
    Search and rescue

    Infrared cameras are indispensable tools for searching and rescueing missed persons, casualties or wreckage debris. All around the clock high-sensitivity infrared sensors can provide substantial aid even under limited visibility conditions, they help to save lives.

  • Active Thermography
    Active thermography

    Make use of active thermography for non-destructive and contact-free material testing, for both automated inline and offline solutions.

  • Micro-Thermography
    Micro-Thermography

    Micro-thermography allows for the thermal analysis of extremely small structures in the micrometer range, providing a detailed representation of the temperature distribution on complex electronic assemblies and components.

  • Aerial Thermography
    Aerial Thermography

    Detec persons and objects in the field or monitor wide-area geologic properties or environmental damages.

  • Thermographic Automation PV-LIT solar cell
    Test system PV-LIT

    Get advantages in costing and quality by non-contact thermographic testing of your solar cells and PV-modules.

  • Thermography for site protection
    Site Surveillance (IROD)

    Monitor free space and buildings using automated infrared camera solutions against illeagal entries.

  • Thermographic Automation Stationary Industrial Solutions
    Stationary industrial solutions

    Gain competitive edge by bespoke and innovative automation solution with high quality and industrial proof thermal images and components.

  • Thermographic Automation Brake test bench
    Brake test bench

    Check for long-life fatigue strength of mechanical components in load tests, using high-end infrared cameras.

  • Thermography in human medicine
    Human medicine

    Being non-contact and non-invasive thermography is a widely accepted diagostic method.

  • Thermography in veterinary medicine
    Veterinary medicine

    Using thermography quickly make accurate diagnosis in a wide field of illnesses.

  • Thermal image of a vulcano
    Thermographic biologic and geologic studies

    Look for smallest temperature differences in landscapes, biotopes and labs using infrared camera models of highest measurement precision.